Medium-/Low Pressure Steam Conditioning Valve DCE

Function


 Pressure and temperature control

Application


 Medium-/low pressure turbine Bypass without safety function to the condenser
 Steam transfer in case of turbine failure
 Steam conditioning for process steam lines

Design


 
Construction:
angular-/Z-form
 
Seat-Ø:
72 - 450 mm
 
Capacity:
K-values from 50m3/h until 400 m3/h
 
Injection:
secondary atomized steam injection or controlled pressure atomizing or spindle injection with atomized steam
 
Throttling:
controlled/uncontrolled
 
Actuator:
hydraulic, electrical or pneumatic
 
Characteristic:
linear/equal percentage
 
Body:
forged and welded materials and pipe connection in accordance with customer specification
 
Leakage rate:
DIN 3230 part 3 - leakage rate 1
as well as ANSI/FCI 70-2
Class V possible
 
Mounting position:
vertical, horizontal and hanging

 